Corn Belt Energy Corporation
Electric cooperativeIllinoisWebsite ↗
- Customers (2025)
- 37,468
- Meters
- 37,468
- Smart meters (AMI)
- 0 (0%)
- Radio-read meters (AMR)
- 37,468 (100%)
- Grid region
- RFC · MISO
- EIA utility number
- 4362
Counts: EIA Form 861, data year 2025.
Meters installed
Landis+Gyr· Landis+Gyr Gridstream RF (Gridstream Connect RF mesh)Current
RF mesh · 2024–2024 [source, unverified]
Models: FOCUS AXR-SD
Illinois Country Living, May 2024 (Corn Belt page): AMI upgrade began early spring 2024, contractor meter change-outs from mid-May, all main meters to be replaced within about six months; fixed-network two-way system with daily and hourly data in SmartHub. Pictured meter faceplate reads 'FOCUS AXRe-SD ... CORN BELT ENERGY' (read from the photo), so Landis+Gyr FOCUS AXR-SD; Gridstream RF network inferred from the meter, not stated. Completion not confirmed (EIA 2024 still lists AMR). Re-checked 2026-11-16: Corn Belt 2024 annual report (search snippet) says the AMI project is well underway and expected to be complete within the next few months; no completion notice found (Sept 2024 and Dec 2025 Powerline read: no AMI items); no primary source names the network. Vendor rests on the faceplate photo.
Vendor not knownReplaced
[source, unverified]
Meters in place before the 2024 AMI upgrade, which replaces all main meters; vendor and technology of the old system not stated in the co-op's notice. Re-checked 2026-11-16: no primary source found for the pre-2024 meter system (looked: Corn Belt Powerline 2024-2025, ICL archive search).
Getting your usage data
- Online account
- cornbeltenergy.smarthub.coop
- Interval you can see
- Hourly
- Available
- Next day
- Green Button
- Not stated
- Pair a device to the meter
- Not stated
- Meter radio readable with an SDR
- No
- Smart meter opt-out
- Not stated
- Research
- Researched [source]
Usage Concerns page: log in to SmartHub to view hourly, daily and monthly use with temperature data. Latency assumed next-day (NISC SmartHub norm, not stated). Landis+Gyr FOCUS AXR-SD on Gridstream RF (inferred): not ERT.
Meter types over time
Counties served
Illinois: Bureau, Champaign, DeWitt, Ford, Henry, Kendall, Knox, LaSalle, Livingston, Logan, Macon, Marshall, McLean, Piatt, Putnam, Stark, Tazewell, Woodford
EIA lists a county when the utility serves any part of it.
Get live readings from your own meter