Sensus iCon APX
Polyphase
- Family
- iCon
- Radios and ports
- Other, Optical port, Test LED pulses
- Readable with rtlamr
- No
- Networks
- Sensus FlexNet
- Source
- [source]
Solid-state bidirectional polyphase S-base meter (120-480 V, 2-200 A, 3-element 4-wire wye in the approval); energy and demand, internal pulse recorder; LED pulse output in the optical port; FlexNet module (licensed P2MP, radio=other). Measurement Canada AE-1728 dated 2010-05-05. K.C. Electric CO used ~2,200 for commercial and irrigation members (2012).
Reading it yourself
- The test LED flashes once per Kh watt-hours. A light sensor on the glass gives live power. How →
Get live readings from your own meter
We are building Utility Brain, a small receiver that reads your electric meter the way your utility does and shows your usage minute by minute. Join the list and we'll tell you when it works with your meter.